Descriptions:
The meter is fully in conformity with the
relevant technical
requirements of GB/T17215.321-2008 national standard and the IEC62053
international standard of grade 1 or level 2 single-phase energy meter,
which can directly and accurately measure active energy of the energy
consumption. It features high reliability, small volume, light weight, beautiful
appearance, advanced technology, and 35mmDIN standard
guide rail installation, etc.
Features:
-
The meter is fully in conformity with the relevant technical
requirements of GB/T17215.321-2008 national standard and the IEC62053 international standard of grade 1 or level 2 single-phase energy meter,
which can directly and accurately measure active energy of the energy consumption.
-
LCD display is 7+1 or 6+1meter shows the total power consumption.
-
It features high reliability, small volume, light weight, beautiful
appearance, advanced technology, and 35mmDIN standard
guide rail installation, etc.
-
It has good anti-electromagnetic interference, low power consumption,
high precision, high overload, high stability, anti electricity-stolen and long
life.
-
This table is suitable for the measurement of rated frequency 50 Hz or
60 Hz single-phase ac active electricity, used for fixed installation
indoors, apply to the environment temperature is -25 ℃ ~ 55
℃, relative humidity is ≤ 95%, and in the air does not
contain corrosive gases and avoid dust, mold, salt fog, condensation,
insects, etc.
Specifications:
Model: DDS5188
Phase number: single phase
Type: guide type
Display mode: LCD
Rated voltage: 220V
Rated current: 5-32A
Working temperature: -25 ℃ ~ 55 ℃
Rated frequency: 50-60Hz +/- 10%
Accuracy level: level 1 (equivalent to measurement error < 1%)
Including S0 port 2000Imp/kWh (ti = 80ms)
Relative humidity: 95%
Size: as the picture
Weight:98g
Wiring diagram:
Test: The meter has photoelectric coupling type electric pulse test output port, located in terminal button box (as shown in figure 2), + 5 VDC of the test equipment connected to 20" + "terminal, signal S connected to 21"-" terminal.
Installation considerations:
1. Installation of Electric Meter required experienced electrician or professionals.
2.Electric meter should be installed in indoor ventilated and dry place, adopt 35mmDIN standard guide type installation, the bottom plate of the electric energy meter shall be fixed to the rigid refractory, non-vibrating wall.
3.The bottom plate of the electric energy meter shall be fixed to the rigid refractory, non-vibrating wall.
4. Electricity meters should be installed in protective cabinets in places where there are filth and potential damages.
5. The installation should be in accordance with the wiring diagram, preferably with a multi-strand copper wire, avoiding the abnormal or burning of the electricity meter because of the bad contact.
6. When the electricity meter is correctly connected to the power grid, the power indicator of the meter is on
7. Electric energy meter should take the lightning protection measures when it is used in the area with more lightning, so as to avoid damaging the electric energy meter by lightning.
The load capacity of the electricity meter is 0.05ib ~ Imax (direct access)
Power indication: when the green light on, indicates that working power supply is normal
Pulse indication: when the red light on, indicates that the power pulse is detected
When there is a sampling signal, the pulse light is about 80ms
Package Included:
1 x Din-rail energy meter
-
We accept PayPal .
-
We ship item to your PayPal
verified address.
-
Payment must be received within 3
days from the date of purchase.
-
All the items will be dispatched
within one business day by Airmail after the payment is clear.
-
Most times you will receive your
order within 10-30 business days after we transfer your package to
the delivery company. We cannot guarantee the delivery timeframe if
the post office has any unexpected delays due to holiday, weather,
customs, or other conditions. Some countries like Russia, Brazil, or
some European countries may take up to 50 days or longer for
delivery.
-
We appreciate your patience if you
haven't received items in 30 days(Russian customers may need more
patience by reason of the local delivery system and/or customs). If
you are concerned in any way, please feel free to contact us via
ebay message instead of leaving
negative/neutral feedback or opening a dispute . We will
do our best to solve any problem(resend or refund any missing
item).
-
Customs duty is obligation and
liability of citizen s in your country, so buyer should be
responsible for any tax and custom duty incurred. Generally, the
delay or failure delivery is sometimes caused by the policy of
different customs.
1. Our listing price includes the value of goods,packaging cost,and export taxes,not including international duties.
2. duties,taxes,and charges are not included in the item price or shipping fee.
3. T he duties are buyers' responsibility .Please check with your country's customs office determine what these additional costs will be prior to your purchase.
4. All disputes arising from the duties will be submitted to ebay for solution.
1. Any questions, pls. contact us via ebay message or email us. We
will reply your message within 48 hours. If you do not receive our
reply within 48 hours, pls. post a message again because sometimes our
message system may block some emails.
2. If you are satisfied with our service, pls. kindly leave us a
positive feedback and give us the Detailed Seller Rating with all " 5 " in very area
3. Our aim is to provide Level Customer Service, your recognition will encourage us greatly and serve you better. We strive to keep all our customers satisfy.
We will do our up most to exceed your expectations in customer service, communication and dispatching of your orders.
|